![]() (Optional) Drag the Messages above or below their execution specification to break the Messages off their execution specification and connect them to the new ones.Drag the selected Messages up or down the execution specification to reposition them.Dependent Messages are then selected automatically. On the diagram pane, select the Message you want to move.On the diagram palette, click the Move Dependent Messages button.If the Message is dragged above or below its execution specification, the latter will break and the Message, along with its dependent Messages, will be connected to the new execution specifications. You can also move a Message together with its dependent Messages up or down the lifeline by dragging it along its execution specification. If you want to move a Message up or down along with all of the subsequent Messages, as well as break the existing execution specification and connect the Messages to the new execution specifications, you can use Magnet and Pusher buttons. Moving a Message together with subsequent Messages (Optional) Drag the Message above or below its execution specification to break the Message off its execution specification and connect it to a new one.Select the Message and drag it up or down the execution specification to reposition it.If the Message is dragged above or below its execution specification, the latter will break and the Message will be connected to a new execution specification. You can move an individual Message up or down the lifeline simply by dragging it along its execution specification. Create or select an incoming Message that is modeled as a callback Message.Then, these would be in one sequence diagram. So, Thread 1 (controller thread) starts, spawns 3 threads, they process and report back to controller. You may want to do related threads together, as separate programs. From the Message shortcut menu, select Create Nested Activation. Handling multiple threads will be a bit daunting, as, part of the reason for using threads is that they are autonomous.Be sure this is not the first one for the outgoing activation. Create an outgoing Message or select an existing Message pointed to an active object.All activations of the selected Lifeline become all-in-one. Select a Lifeline and from its shortcut menu, select Show Entire Activation.This property is available in the Expert mode. ![]() The active Class is the one whose Is Active property is set to true.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |